引用本文: 刘红文, 季颖, 宋春丽, 田刚, 李诗雅, 杨桂英, 吕昌银. 铅离子诱导PS2.M构象改变特性及其氡非标记比色传感检测新方法. 分析化学, 2018, 46(5): 658-663. doi: 10.11895/j.issn.0253-3820.171151 [复制]
Citation: LIU Hong-Wen, JI Ying, SONG Chun-Li, TIAN Gang, LI Shi-Ya, YANG Gui-Ying, LYU Chang-Yin. Pb2+-Induced Allosteric PS2.M as A Label-Free Colorimetric Sensor for Detection of Cumulative Radon Radiation. Chinese Journal of Analytical Chemistry, 2018, 46(5): 658-663. doi: 10.11895/j.issn.0253-3820.171151 [复制]
铅离子诱导PS2.M构象改变特性及其氡非标记比色传感检测新方法
Pb2+-Induced Allosteric PS2.M as A Label-Free Colorimetric Sensor for Detection of Cumulative Radon Radiation
以氡辐射衰变最终形成稳定的子体铅作为目标检测物,建立了检测氡累积浓度的核酸适配体生物分析新方法。K+诱导富G单链核苷酸PS2.M形成反平行G-四链体四链体,辅因子血红素与G-四联链体结合,形成具有过氧化物酶活性的稳定复合物,催化TMB-H2O2体系发生显色反应。同时加入Pb2+时,Pb2+诱导PS2.M形成结构更加稳定的"缺口"型反平行G-四链体,K+和血红素游离在溶液之中,体系吸光度响应值急剧降低。基于此构建了一种基于Pb2+诱导PS2.M构象改变的过氧化物酶活性"Turn-off"型比色传感器。在5.0×10-9~1.8×10-7 mol/L范围内,吸光度降低值ΔA与Pb2+浓度呈线性关系,线性回归方程为ΔA=0.36+0.13C,R=0.9987。本方法对Pb2+的检出限为3.76 nmol/L(S/N=3),氡的检出限为1.96×103 Bq·h/m3(S/N=3)。本方法灵敏、准确,样品溶液可直接检测,操作简单,避免了现场进行氡辐射剂量测量的放射性危害,为环境中氡的检测提供了新方法。
A new sensitive method for detection of cumulative radon radiation based on the lead was established. PS2.M which stabilized by K+ with hemin as a co-factor exhibits superior peroxidase-like activity, and can effectively catalyze the H2O2-mediated oxidation of TMB. In the presence of Pb2+, K+-stabilized PS2.M DNAzymes are induced to undergo a conformational change, because Pb2+ has a higher efficiency with regard to stabilizing G-quadruplexes than K+, accompanied by a decrease of catalytic activity and a sharp decrease of readout signal. In the work, a novel "turn-off" model of colorimetry-Pb2+ biosensor based on superior peroxidase-like activity of G-quadruplex for Pb2+ analysis was developed. The fading degree of reaction system (ΔA value) was linearly related to Pb2+ concentration in the range of 5.0×10-9-1.8×10-7 mol/L. The linear regression equation was ΔA=0.36+0.13C (10-8 mol/L), with R=0.9987. The detection limits of lead and radon were 3.76 nmol/L(S/N=3) and 1.96×103 Bq·h/m3(S/N=3), respectively. The method exhibited good selectivity, high sensitivity and convenient operation, and could avoid the radioactive hazard in determination of the radon in environment.
[1] |
Inácio M, Soares S, Almeida P. J. Radiat. Res. Appl. Sci., 2017, : -. doi: 10.1016/j.jrras.2017.02.002 |
[2] |
Midhun M, Rejith R S, Samuel M, Jojo P J, Sahoo B K. International Journal of Pure and Applied Physics., 2017, 13(1): 172-178 |
[3] |
Kendall G M, Smith T J. J. Radiol. Prot., 2002, 22(4): 389-406. doi: 10.1088/0952-4746/22/4/304 |
[4] |
ZHANG Dong-Sheng, ZHANG Wei, MA Li-Qiang, WANG Xu-Feng, FAN Gang-Wei. Journal of China University of Mining & Technology, 2016, 45(6): 1083-1097 |
[5] |
McColl N P, Green B M R, Dixon D W, Fey R, Meara J R, Harrison J D, Cooper J R. Centre for Radiation, Chemical and Environmental Hazards. London: Health Protection Agency, 2010 |
[6] |
Klervi L, Maria S, Ladislav T, Nezahat H, Margot T, Bernd G, Michaela K, Dominique L. Radiat. Res., 2011, 176(3): 375-387. doi: 10.1667/RR2377.1 |
[7] |
TIAN Rong, LIU Ying-Yun. Journal of Environmental Engineering Technology, 2016, (1): 35-42 |
[8] |
Kreuzer M, Fenske N, Schnelzer M, Walsh L. Br. J. Cancer, 2015, 113: 1367-1369. doi: 10.1038/bjc.2015.324 |
[9] |
Farokhzad O C, Jon S, Khademhosseini A, Tran T N, Lavan D A, Langer R. Cancer Res., 2004, 64(21): 7668-7672. doi: 10.1158/0008-5472.CAN-04-2550 |
[10] |
Hernandez R, Valles C, Benito A M, Maser W K, Rius F X, Riu J. Biosens. Bioelectron., 2014, 54: 553-557. doi: 10.1016/j.bios.2013.11.053 |
[11] |
Kikuchi K, Umehara T, Nishikawa F, Fukuda K, Hasegawa T, Nishikawa S. Biochem. Biophys. Res. Commun., 2009, 386(1): 118-123. doi: 10.1016/j.bbrc.2009.05.135 |
[12] |
Liu B. Biosens Bioelectron, 2008, 24(4): 762-766 |
[13] |
Jiang Z, Fan Y, Chen M, Liang A, Liao X, Wen G, Shen X, He X, Pan H, Jiang H. Anal. Chem., 2009, 81(13): 5439-5445. doi: 10.1021/ac900590g |
[14] |
Lu Y, Li X, Wang G, Tang W. Biosens. Bioelectron., 2013, 39(1): 231-235. doi: 10.1016/j.bios.2012.07.045 |
[15] |
DENG Huan, SUN Mi, WEI Xiao-Ping, LI Hong-Zeng, LI Jian-Ping. Chinese J. Anal. Chem., 2016, 44(6): 888-892 |
[16] |
Long M, Deng H, Tian G, Song C, Liu H, Shen Y, Lv C. Anal. Chim. Acta, 2016, 936: 202-207. doi: 10.1016/j.aca.2016.06.025 |
[17] |
Deng H, Long M, Tian G, Song C, Liu H, Hu L, Lv C. RSC Adv., 2016, 43(6): 37254-37257 |
[18] |
Arola A, Vilar R. Curr. Top. Med. Chem., 2008, 8(15): 1405-1415. doi: 10.2174/156802608786141106 |
[19] |
Li T, Wang E, Dong S. Anal. Chem., 2010, 82(4): 1515-1520. doi: 10.1021/ac902638v |
[20] |
Jing T, Dai Y, Ma X J, Huang B B. Chinese Optic, 2016, 9(1): 1-15 |
[21] |
Kong D M, Xu J, Shen H X. Anal. Chem., 2010, 82(14): 6148-6153. doi: 10.1021/ac100940v |
[22] |
Zhou X H, Kong D M, Shen H X. Anal. Chem., 2010, 82(3): 789-793. doi: 10.1021/ac902421u |
[23] |
Li T, Wang E, Dong S. J. Am. Chem. Soc., 2009, 131(42): 15082-15083. doi: 10.1021/ja9051075 |
[24] |
Smirnov I, Shafer R H. J. Mol. Biol., 2000, 296(1): 1-5. doi: 10.1006/jmbi.1999.3441 |
[25] |
Smirnov I, Kotch F, Pickering I, Davis J, Shafer R. Biochemistry, 2002, 41(40): 12133-12139. doi: 10.1021/bi020310p |
[26] |
GB/T16146-2015, Requirements for Control of Indoor Radon and Its Progeny. National Standards of the People's Republic of China 室内氡及其子体控制要求. 中华人民共和国国家标准. GB/T 16146-2015 |
[27] |
GB/T18883-2002, Indoor Air Quality Standard. National Standards of the People's Republic of China 室内空气质量标准. 中华人民共和国国家标准. GB/T18883-2002 |
[28] |
GB/T 14582-1993, Standard Methods for Radon Measurement in Environmental Air. National Standards of the People's Republic of China 环境空气中氡的标准测量方法. 中华人民共和国国家标准. GB/T 14582-1993 |
铅离子诱导PS2.M构象改变特性及其氡非标记比色传感检测新方法
Pb2+-Induced Allosteric PS2.M as A Label-Free Colorimetric Sensor for Detection of Cumulative Radon Radiation
计量
- PDF下载量(52)
- 文章访问量(1165)
- HTML全文浏览量(24)