首页 杂志概况 投稿须知 在线投稿 在线阅读 征订启事 广告服务 行业资讯 企业动态 资料中心  专访报道 会展信息 ENGLISH

引用本文:   徐榕, 杨叶欣, 林敏, 李晓东, 冯爱玲. 基于显色法的纸基微流控芯片用于水中的三氮检测. 分析化学, 2020, 48(9): 1202-1209. doi:  10.19756/j.issn.0253-3820.191634 [复制]

Citation:   XU Rong , YANG Ye-Xin , LIN Min , LI Xiao-Dong , FENG Ai-Ling . Paper-based Microfluidic Chip for Detection of 3-Nitrogen in Water Based on Chromogenic Method. Chinese Journal of Analytical Chemistry, 2020, 48(9): 1202-1209. doi: 10.19756/j.issn.0253-3820.191634 [复制]

基于显色法的纸基微流控芯片用于水中的三氮检测

通讯作者:  冯爱玲, ailing@mail.xjtu.edu.cn

收稿日期: 2019-10-28

基金项目: 本文系国家自然科学基金项目(No.51801001)、陕西省重点研发计划(No.2019GY-197)、陕西省自然科学基础研究计划(No.2015JM5215)、中国博士后科学基金面上项目(No.2016M601878)和宝鸡市科技计划项目(No.16RKX1-29)资助

Paper-based Microfluidic Chip for Detection of 3-Nitrogen in Water Based on Chromogenic Method

Corresponding author:  FENG Ai-Ling , ailing@mail.xjtu.edu.cn

Received Date:  2019-10-28

Fund Project:  This work was supported by the National Natural Science Foundation of China (No. 51801001), Provincial Key Research and Development Program of Shaanxi (No. 2019GY-197), the Natural Science Basic Research Plan in Shaanxi Province of China (No. 2015JM5215), and the China Postdoctoral Science Foundation (No. 2016M601878).

硝酸盐、亚硝酸盐和氨氮(简称"三氮")是水体中的主要污染物,目前我国的地表水和浅层地下水中普遍存在三氮污染问题。本研究将显色法与纸基微流控技术结合,制备了单通道纸基微流控芯片,在优化的反应条件下,分别对3种含氮化合物进行检测,亚硝酸盐、硝酸盐和氨氮的检出限分别为0.001 mmol/L、1 mmol/L和1 mg/L;在实际样本的检测中,3种样本的加标回收率均在95.4%~114.9%之内。其次,通过合理的结构设计将分别用于3种含氮化合物检测的单通道纸基微流控芯片集成于一体,制备出用于三氮同时检测的多通道纸基微流控芯片,多通道纸基微流控芯片的检测结果与单通道纸基微流控芯片的检测结果具有良好的一致性。本研究提出的基于显色法的多通道纸基微流控芯片可对水中的三氮进行同时检测,并且,此芯片具有成本低廉、灵敏度高和便于操作等特点,适用于现场快速检测,有望在资源匮乏的水源污染地区推广。

关键词:   显色法, 三氮检测, 纸基微流控
Key words:   Chromogenic method, 3-Nitrogen detection, Paper-based microfluidic chip
[1]

Yu C Q, Huang X, Chen H, Godfray H C J, Wright J S, Hall J W, Gong P, Ni S Q, Qiao S C, Huang G R, Xiao Y C, Zhang J, Feng Z, Ju X T, Ciais P, Stenseth N C, Hessen D O, Sun Z L, Yu L, Cai W J, Fu H H, Huang X M, Zhang C, Liu H B, Taylor J. Nature,2019,567(7749):516-520

[2]

Landrigan P J, Fuller R, Acosta N J R, Adeyi O, Arnold R, Basu N, Balde A B, Bertollini R, Bose-O'Reilly S, Boufford J I, Breysse P N, Chiles T, Mahidol C, Coll-Seck A M., Cropper M L, Fobil J, Fuster V, Greenstone M, Haines A, Hanrahan D, Hunter D, Khare M, Krupnick A, Lanphear B, Lohani B, Martin K, Mathiasen K V, McTeer M A., Murray C J L, Ndahimananjara J D, Perera F, Potocnik J, Preker A S, Ramesh J, Rockstrom J, Salinas C, Samson L D, Sandilya K, Sly P D, Smith K R, Steiner A, Stewart R B, Suk W A, van Schayck Onno C P, Yadama G N, Yumkella K, Zhong M. Lancet,2018,391(10119):462-512

[3]

Zhu Z L, Guan X D, Zheng H T, Yang C, Xing Z, Hu S H. J. Anal. Atom. Spectrom.,2018,33(12):2153-2159

[4]

Correa-Duarte M A, Perez N P, Guerrini L, Giannini V, Alvarez-Puebla R A.J. Phys. Chem. Lett.,2015,6(5):868-874

[5]

Baciu A, Manea F, Pop A, Pode R, Schoonman L.Proc. Safety Environ. Protect.,2017,108:18-25

[6]

Oh J W, Chung W J, Heo K, Jin H E, Lee B Y, Wang E, Zueger C, Wong W, Meyer J, Kim C, Lee S Y, Kim W G, Zemla M, Auer M, Hexemer A, Lee S W. Nat. Commun.,2014,5:3043

[7]

Cho Y B, Jeong S H, Chun H, Kim Y S. Sens. Actuators B,2018,256:167-175

[8]

Jin B R, Yang Y X, He R Y, Park Y I, Lee A, Bai D, Li F, Lu T J, Xu F, Lin M. Sens. Actuators B,2018,276:48-56

[9]

You M L, Lin M, Gong Y, Wang S R, Li A, Ji L Y, Zhao H X, Ling K, Wen T, Huang Y, Gao D F, Ma Q, Wang T Z, Ma A Q, Li X L, Xu F. ACS Nano,2017,11(6):6261-6270

[10]

Xia Y Y, Si J, Li Z Y. Biosens. Bioelectron.,2016,77:774-789

[11]

Jayawardane B M, Wei S, McKelvie I D, Kolev S D. Anal. Chem.,2014,86(15):7274-7279

[12]

Sun J, Zhang X J, Broderick M, Fein H. Sensors, 2003,3(8):276-284

[13]

Lau K T, Edwards S, Diamond D. Sens. Actuators B,2004,98(1):12-17

[14]

Zheng X J, Liang R P, Li Z J, Zhang L, Qiu J D. Sens. Actuators B,2016,230:314-319

[15]

Lin K N, Ma J, Yuan D X, Feng S C, Su H T, Huang Y M, Shanguan Q P. Talanta,2017,167:166-171

计量
  • PDF下载量(26)
  • 文章访问量(291)
  • HTML全文浏览量(8)

目录

基于显色法的纸基微流控芯片用于水中的三氮检测

徐榕, 杨叶欣, 林敏, 李晓东, 冯爱玲

Figures and Tables